Sale!

Features & Details

🧊 JACKETED TEMP CONTROL Water circulates through a double jacket that wraps both chambers of the H-type electrolytic cell, holding the test solution at a steady set point.
🔀 2/3/4-ELECTRODE PORTS Two ports for a simple working-counter pair, three with a side neck for a reference electrode, four with an added gas port.
🔧 QUICK MEMBRANE SWAP A stainless clamp on the middle flange releases in seconds, so a fouled membrane is replaced without draining either chamber.
📐 5-500 ML PER CHAMBER Twenty-two combinations from 5 ml microcells to 500 ml preparative cells, in frosted or screw thread seal.

About this item

Feature Description
Brand Xin Tester®
Product Type H-type electrolytic cell, double jacketed with replaceable membrane
Chamber Volume 5 to 500 ml per chamber
Configurations 22 combinations, single part number per size and port layout
Chambers 2 (Double) as standard, 3 (Triple) on 5 / 10 / 20 / 50 ml
Electrode Ports 2-, 3- or 4-electrode layouts
Seal Style Frosted ground joint or screw thread
Body Material High borosilicate glass
Lid Material PTFE
Temperature Control Double-layer water jacket surrounding both chambers
Membrane Replaceable, secured by a stainless steel flange clamp
Included Jacketed cell body, PTFE lid, gaskets, electrode fixing rings
Sold Separately Electrodes, ion membrane, circulating bath
This Xin Tester® H-type electrolytic cell runs both chambers inside one water jacket, with a membrane that swaps out through the middle flange in a few minutes. It is built in 22 configurations from 5 ml to 500 ml, with 2-, 3- or 4-electrode ports and either a frosted or a screw thread seal.

H-Type Electrolytic Cell

Two Chambers, One Stable Temperature

Coulometric and potentiometric work punishes temperature drift. This H-type electrolytic cell circulates water through a double jacket that wraps both chambers, holding the working solution at a set point while the ion membrane keeps the anolyte and catholyte chemistry apart. Pick the chamber volume, electrode count and seal style that matches your method, from 5 ml microcells up to 500 ml preparative setups.

Why Choose This H-Type Electrolytic Cell?

Precise Temperature Control

The double-layer jacket circulates constant-temperature water around both chambers, stabilizing the test solution so electrochemical readings stay accurate and reproducible run after run.

Split-Chamber Isolation

The H-type electrolytic cell keeps the cathode and anode chambers independent. A user-supplied ion membrane between them cuts cross-interference between the two half-reactions and lowers solution resistance for cleaner curves.

Chemical-Resistant Build

A high borosilicate glass body with a chemical-resistant PTFE lid stands up to the common electrolyte systems, so the cell keeps its clarity and its seal through repeated cycles.

Quick Membrane Swap

A stainless steel clamp seals the middle flange tightly and releases in seconds, so changing a fouled or torn membrane does not mean draining the whole cell or dismantling the jacket.

Versatile Port Configuration

Sizes run from 5 ml to 500 ml per chamber, with standard electrode and vent ports that accept most two- and three-electrode setups. Two, three and four electrode versions of the H-type electrolytic cell share the same footprint.

Configuration Range

H-type electrolytic cell range with 2-, 3- and 4-electrode jacketed bodies from 5 ml to 500 ml

Chamber Volume 5, 10, 20, 30, 50, 60, 100, 150, 200, 300, 400, 500 ml per chamber
Chambers 2 (double) as standard, 3 (triple) on selected small volumes
Electrode Ports 2, 3 or 4 electrode configurations
Seal Style Frosted ground joint or screw thread
Body Material High borosilicate glass
Lid Material PTFE
Membrane Replaceable, held by a stainless steel flange clamp (membrane supplied separately)

What Is Included

Each H-type electrolytic cell ships as a complete glass assembly ready to connect to a circulator: the jacketed cell body, a PTFE lid, gaskets and the electrode fixing rings. Exact contents differ between the double-chamber and triple-chamber versions.

Electrodes, the ion membrane and the circulating bath are not part of the shipment. They are ordered separately so you can match the membrane type and electrode material to your own chemistry.

Pairing And Scale-Up

Most H-type electrolytic cell setups start with one cell and grow into a bench system. A jacketed beaker covers bulk thermostatted volumes on the same water loop, and a 3-neck reaction flask handles the preparative step after electrolysis. The rest of the range sits under lab glassware.

FAQs

A: A 2-electrode cell carries one electrode port in each chamber, for the working and the counter electrode. The 3-electrode version adds a 12 mm side neck for a reference electrode, which is what most potentiostat methods call for. The 4-electrode version adds a gas port as well, so you can sparge or vent without pulling a stopper.

A: The standard H-type electrolytic cell has two chambers. The Triple version puts a third chamber on the same footprint, so the middle compartment can hold a reference electrode or a second electrolyte without assembling a separate cell next to it.

A: No. The ion membrane, the electrodes and the circulating bath are ordered separately, so you can match the membrane type and the electrode material to your own chemistry. The shipment is the H-type electrolytic cell body with its jacket, a PTFE lid, gaskets and the electrode fixing rings.

A: Frosted ground joints hold by friction and suit routine bench work, where the cell is set up and taken apart by hand. Screw thread ports take a threaded collar, so they stay tight under pressure or vibration and are easier to automate.

H-Type Double Jacketed Electrolytic Cell Replaceable Membrane (5-500 ml, 2/3/4-Electrode)

Price range: $50.64 through $209.07

6–12 Month Warranty

Repair & Refund support available for most products.

Free Worldwide Shipping

Ships within 3 business days.

Taxes & Duties

Buyer responsible for local import fees.

24/7 After-Sales Support

Technical assistance & video guidance within 24h.

H-Type Double Jacketed Electrolytic Cell Replaceable Membrane (5-500 ml, 2/3/4-Electrode)

Sale!

Price range: $50.64 through $209.07

Features & Details

🧊 JACKETED TEMP CONTROL Water circulates through a double jacket that wraps both chambers of the H-type electrolytic cell, holding the test solution at a steady set point.
🔀 2/3/4-ELECTRODE PORTS Two ports for a simple working-counter pair, three with a side neck for a reference electrode, four with an added gas port.
🔧 QUICK MEMBRANE SWAP A stainless clamp on the middle flange releases in seconds, so a fouled membrane is replaced without draining either chamber.
📐 5-500 ML PER CHAMBER Twenty-two combinations from 5 ml microcells to 500 ml preparative cells, in frosted or screw thread seal.
Feature Description
Brand Xin Tester®
Product Type H-type electrolytic cell, double jacketed with replaceable membrane
Chamber Volume 5 to 500 ml per chamber
Configurations 22 combinations, single part number per size and port layout
Chambers 2 (Double) as standard, 3 (Triple) on 5 / 10 / 20 / 50 ml
Electrode Ports 2-, 3- or 4-electrode layouts
Seal Style Frosted ground joint or screw thread
Body Material High borosilicate glass
Lid Material PTFE
Temperature Control Double-layer water jacket surrounding both chambers
Membrane Replaceable, secured by a stainless steel flange clamp
Included Jacketed cell body, PTFE lid, gaskets, electrode fixing rings
Sold Separately Electrodes, ion membrane, circulating bath
This Xin Tester® H-type electrolytic cell runs both chambers inside one water jacket, with a membrane that swaps out through the middle flange in a few minutes. It is built in 22 configurations from 5 ml to 500 ml, with 2-, 3- or 4-electrode ports and either a frosted or a screw thread seal.

H-Type Electrolytic Cell

Two Chambers, One Stable Temperature

Coulometric and potentiometric work punishes temperature drift. This H-type electrolytic cell circulates water through a double jacket that wraps both chambers, holding the working solution at a set point while the ion membrane keeps the anolyte and catholyte chemistry apart. Pick the chamber volume, electrode count and seal style that matches your method, from 5 ml microcells up to 500 ml preparative setups.

Why Choose This H-Type Electrolytic Cell?

Precise Temperature Control

The double-layer jacket circulates constant-temperature water around both chambers, stabilizing the test solution so electrochemical readings stay accurate and reproducible run after run.

Split-Chamber Isolation

The H-type electrolytic cell keeps the cathode and anode chambers independent. A user-supplied ion membrane between them cuts cross-interference between the two half-reactions and lowers solution resistance for cleaner curves.

Chemical-Resistant Build

A high borosilicate glass body with a chemical-resistant PTFE lid stands up to the common electrolyte systems, so the cell keeps its clarity and its seal through repeated cycles.

Quick Membrane Swap

A stainless steel clamp seals the middle flange tightly and releases in seconds, so changing a fouled or torn membrane does not mean draining the whole cell or dismantling the jacket.

Versatile Port Configuration

Sizes run from 5 ml to 500 ml per chamber, with standard electrode and vent ports that accept most two- and three-electrode setups. Two, three and four electrode versions of the H-type electrolytic cell share the same footprint.

Configuration Range

H-type electrolytic cell range with 2-, 3- and 4-electrode jacketed bodies from 5 ml to 500 ml

Chamber Volume 5, 10, 20, 30, 50, 60, 100, 150, 200, 300, 400, 500 ml per chamber
Chambers 2 (double) as standard, 3 (triple) on selected small volumes
Electrode Ports 2, 3 or 4 electrode configurations
Seal Style Frosted ground joint or screw thread
Body Material High borosilicate glass
Lid Material PTFE
Membrane Replaceable, held by a stainless steel flange clamp (membrane supplied separately)

What Is Included

Each H-type electrolytic cell ships as a complete glass assembly ready to connect to a circulator: the jacketed cell body, a PTFE lid, gaskets and the electrode fixing rings. Exact contents differ between the double-chamber and triple-chamber versions.

Electrodes, the ion membrane and the circulating bath are not part of the shipment. They are ordered separately so you can match the membrane type and electrode material to your own chemistry.

Pairing And Scale-Up

Most H-type electrolytic cell setups start with one cell and grow into a bench system. A jacketed beaker covers bulk thermostatted volumes on the same water loop, and a 3-neck reaction flask handles the preparative step after electrolysis. The rest of the range sits under lab glassware.

Customer Reviews

Reviews

There are no reviews yet

Add a review
You must be logged in to post a review Log In

Discover More from Xin Tester

Technical diagram of a 125ml pear-shaped separatory funnel.Two pear-shaped separatory funnels filled with blue liquid on a black background.

Pear-Shaped Separatory Funnel, Borosilicate 3.3 Glass with Glass Stopcock (60ml-1000ml)

Price range: $12.51 through $28.33

🚚 Delivery: as soon as Thu. Dec 17

Select options This product has multiple variants. The options may be chosen on the product page
20000ml amber glass reagent bottleClear and amber GL45 glass reagent bottles

Xin Tester GL45 Reagent Bottle, 100ml-20L Boro 3.3 Glass with Anti-Slip Bottom

Price range: $19.91 through $286.00

🚚 Delivery: as soon as Thu. Dec 17

Select options This product has multiple variants. The options may be chosen on the product page
Set of borosilicate glass graduated cylinders in various sizesResearcher performing experiment with glass graduated cylinder

Xin Tester Glass Graduated Cylinder (25ml & 50ml), Ex 20°C BORO 3.3 High Borosilicate Lab Liquid Measurement

Price range: $7.59 through $68.42

🚚 Delivery: as soon as Thu. Dec 17

Select options This product has multiple variants. The options may be chosen on the product page
A pair of clear and amber medical ampoules20ml clear glass medical ampoule 100pcs pack

Glass Ampoules, Clear & Amber Empty Vials with Easy-Break Neck (1ml-20ml) by Xin Tester

Price range: $12.84 through $52.78

🚚 Delivery: as soon as Thu. Dec 17

Select options This product has multiple variants. The options may be chosen on the product page
Full assembly of Xin Tester vacuum filtration apparatus with filtering flask and funnel-1000mlSand core head of filtration apparatus compatible with 50mm membrane filter paper.

Xin Tester Glass Vacuum Filtration Apparatus Assembly (250-1000ml)

Price range: $60.87 through $68.98

🚚 Delivery: as soon as Thu. Dec 17

Select options This product has multiple variants. The options may be chosen on the product page
Set of various size borosilicate glass erlenmeyer flasksClear and amber laboratory glass flasks side by side

Threaded Erlenmeyer Flask, Boro 3.3 Glass with Screw Cap & Anti-Drip Ring (50ml-2000ml) by Xin Tester

Price range: $8.99 through $47.99

🚚 Delivery: as soon as Thu. Dec 17

Select options This product has multiple variants. The options may be chosen on the product page