Features & Details
| 🧊 JACKETED TEMP CONTROL | Water circulates through a double jacket that wraps both chambers of the H-type electrolytic cell, holding the test solution at a steady set point. |
| 🔀 2/3/4-ELECTRODE PORTS | Two ports for a simple working-counter pair, three with a side neck for a reference electrode, four with an added gas port. |
| 🔧 QUICK MEMBRANE SWAP | A stainless clamp on the middle flange releases in seconds, so a fouled membrane is replaced without draining either chamber. |
| 📐 5-500 ML PER CHAMBER | Twenty-two combinations from 5 ml microcells to 500 ml preparative cells, in frosted or screw thread seal. |
About this item
| Feature | Description |
|---|---|
| Brand | Xin Tester® |
| Product Type | H-type electrolytic cell, double jacketed with replaceable membrane |
| Chamber Volume | 5 to 500 ml per chamber |
| Configurations | 22 combinations, single part number per size and port layout |
| Chambers | 2 (Double) as standard, 3 (Triple) on 5 / 10 / 20 / 50 ml |
| Electrode Ports | 2-, 3- or 4-electrode layouts |
| Seal Style | Frosted ground joint or screw thread |
| Body Material | High borosilicate glass |
| Lid Material | PTFE |
| Temperature Control | Double-layer water jacket surrounding both chambers |
| Membrane | Replaceable, secured by a stainless steel flange clamp |
| Included | Jacketed cell body, PTFE lid, gaskets, electrode fixing rings |
| Sold Separately | Electrodes, ion membrane, circulating bath |
H-Type Electrolytic Cell
Two Chambers, One Stable Temperature
Coulometric and potentiometric work punishes temperature drift. This H-type electrolytic cell circulates water through a double jacket that wraps both chambers, holding the working solution at a set point while the ion membrane keeps the anolyte and catholyte chemistry apart. Pick the chamber volume, electrode count and seal style that matches your method, from 5 ml microcells up to 500 ml preparative setups.
Why Choose This H-Type Electrolytic Cell?
Precise Temperature Control
The double-layer jacket circulates constant-temperature water around both chambers, stabilizing the test solution so electrochemical readings stay accurate and reproducible run after run.
Split-Chamber Isolation
The H-type electrolytic cell keeps the cathode and anode chambers independent. A user-supplied ion membrane between them cuts cross-interference between the two half-reactions and lowers solution resistance for cleaner curves.
Chemical-Resistant Build
A high borosilicate glass body with a chemical-resistant PTFE lid stands up to the common electrolyte systems, so the cell keeps its clarity and its seal through repeated cycles.
Quick Membrane Swap
A stainless steel clamp seals the middle flange tightly and releases in seconds, so changing a fouled or torn membrane does not mean draining the whole cell or dismantling the jacket.
Versatile Port Configuration
Sizes run from 5 ml to 500 ml per chamber, with standard electrode and vent ports that accept most two- and three-electrode setups. Two, three and four electrode versions of the H-type electrolytic cell share the same footprint.
Configuration Range

| Chamber Volume | 5, 10, 20, 30, 50, 60, 100, 150, 200, 300, 400, 500 ml per chamber |
| Chambers | 2 (double) as standard, 3 (triple) on selected small volumes |
| Electrode Ports | 2, 3 or 4 electrode configurations |
| Seal Style | Frosted ground joint or screw thread |
| Body Material | High borosilicate glass |
| Lid Material | PTFE |
| Membrane | Replaceable, held by a stainless steel flange clamp (membrane supplied separately) |
What Is Included
Each H-type electrolytic cell ships as a complete glass assembly ready to connect to a circulator: the jacketed cell body, a PTFE lid, gaskets and the electrode fixing rings. Exact contents differ between the double-chamber and triple-chamber versions.
Electrodes, the ion membrane and the circulating bath are not part of the shipment. They are ordered separately so you can match the membrane type and electrode material to your own chemistry.
Pairing And Scale-Up
Most H-type electrolytic cell setups start with one cell and grow into a bench system. A jacketed beaker covers bulk thermostatted volumes on the same water loop, and a 3-neck reaction flask handles the preparative step after electrolysis. The rest of the range sits under lab glassware.
FAQs
Q1: What is the difference between the 2-, 3- and 4-electrode versions?
A: A 2-electrode cell carries one electrode port in each chamber, for the working and the counter electrode. The 3-electrode version adds a 12 mm side neck for a reference electrode, which is what most potentiostat methods call for. The 4-electrode version adds a gas port as well, so you can sparge or vent without pulling a stopper.
Q2: What does the Triple version add over the standard Double cell?
A: The standard H-type electrolytic cell has two chambers. The Triple version puts a third chamber on the same footprint, so the middle compartment can hold a reference electrode or a second electrolyte without assembling a separate cell next to it.
Q3: Does the cell ship with the membrane and the electrodes?
A: No. The ion membrane, the electrodes and the circulating bath are ordered separately, so you can match the membrane type and the electrode material to your own chemistry. The shipment is the H-type electrolytic cell body with its jacket, a PTFE lid, gaskets and the electrode fixing rings.
Q4: What is the difference between the frosted seal and the thread seal?
A: Frosted ground joints hold by friction and suit routine bench work, where the cell is set up and taken apart by hand. Screw thread ports take a threaded collar, so they stay tight under pressure or vibration and are easier to automate.
H-Type Double Jacketed Electrolytic Cell Replaceable Membrane (5-500 ml, 2/3/4-Electrode)
$50.64 – $209.07Price range: $50.64 through $209.07
6–12 Month Warranty
Repair & Refund support available for most products.
Free Worldwide Shipping
Ships within 3 business days.
Taxes & Duties
Buyer responsible for local import fees.
24/7 After-Sales Support
Technical assistance & video guidance within 24h.
H-Type Double Jacketed Electrolytic Cell Replaceable Membrane (5-500 ml, 2/3/4-Electrode)
$50.64 – $209.07Price range: $50.64 through $209.07
Features & Details
| 🧊 JACKETED TEMP CONTROL | Water circulates through a double jacket that wraps both chambers of the H-type electrolytic cell, holding the test solution at a steady set point. |
| 🔀 2/3/4-ELECTRODE PORTS | Two ports for a simple working-counter pair, three with a side neck for a reference electrode, four with an added gas port. |
| 🔧 QUICK MEMBRANE SWAP | A stainless clamp on the middle flange releases in seconds, so a fouled membrane is replaced without draining either chamber. |
| 📐 5-500 ML PER CHAMBER | Twenty-two combinations from 5 ml microcells to 500 ml preparative cells, in frosted or screw thread seal. |
| Feature | Description |
|---|---|
| Brand | Xin Tester® |
| Product Type | H-type electrolytic cell, double jacketed with replaceable membrane |
| Chamber Volume | 5 to 500 ml per chamber |
| Configurations | 22 combinations, single part number per size and port layout |
| Chambers | 2 (Double) as standard, 3 (Triple) on 5 / 10 / 20 / 50 ml |
| Electrode Ports | 2-, 3- or 4-electrode layouts |
| Seal Style | Frosted ground joint or screw thread |
| Body Material | High borosilicate glass |
| Lid Material | PTFE |
| Temperature Control | Double-layer water jacket surrounding both chambers |
| Membrane | Replaceable, secured by a stainless steel flange clamp |
| Included | Jacketed cell body, PTFE lid, gaskets, electrode fixing rings |
| Sold Separately | Electrodes, ion membrane, circulating bath |
H-Type Electrolytic Cell
Two Chambers, One Stable Temperature
Coulometric and potentiometric work punishes temperature drift. This H-type electrolytic cell circulates water through a double jacket that wraps both chambers, holding the working solution at a set point while the ion membrane keeps the anolyte and catholyte chemistry apart. Pick the chamber volume, electrode count and seal style that matches your method, from 5 ml microcells up to 500 ml preparative setups.
Why Choose This H-Type Electrolytic Cell?
Precise Temperature Control
The double-layer jacket circulates constant-temperature water around both chambers, stabilizing the test solution so electrochemical readings stay accurate and reproducible run after run.
Split-Chamber Isolation
The H-type electrolytic cell keeps the cathode and anode chambers independent. A user-supplied ion membrane between them cuts cross-interference between the two half-reactions and lowers solution resistance for cleaner curves.
Chemical-Resistant Build
A high borosilicate glass body with a chemical-resistant PTFE lid stands up to the common electrolyte systems, so the cell keeps its clarity and its seal through repeated cycles.
Quick Membrane Swap
A stainless steel clamp seals the middle flange tightly and releases in seconds, so changing a fouled or torn membrane does not mean draining the whole cell or dismantling the jacket.
Versatile Port Configuration
Sizes run from 5 ml to 500 ml per chamber, with standard electrode and vent ports that accept most two- and three-electrode setups. Two, three and four electrode versions of the H-type electrolytic cell share the same footprint.
Configuration Range

| Chamber Volume | 5, 10, 20, 30, 50, 60, 100, 150, 200, 300, 400, 500 ml per chamber |
| Chambers | 2 (double) as standard, 3 (triple) on selected small volumes |
| Electrode Ports | 2, 3 or 4 electrode configurations |
| Seal Style | Frosted ground joint or screw thread |
| Body Material | High borosilicate glass |
| Lid Material | PTFE |
| Membrane | Replaceable, held by a stainless steel flange clamp (membrane supplied separately) |
What Is Included
Each H-type electrolytic cell ships as a complete glass assembly ready to connect to a circulator: the jacketed cell body, a PTFE lid, gaskets and the electrode fixing rings. Exact contents differ between the double-chamber and triple-chamber versions.
Electrodes, the ion membrane and the circulating bath are not part of the shipment. They are ordered separately so you can match the membrane type and electrode material to your own chemistry.
Pairing And Scale-Up
Most H-type electrolytic cell setups start with one cell and grow into a bench system. A jacketed beaker covers bulk thermostatted volumes on the same water loop, and a 3-neck reaction flask handles the preparative step after electrolysis. The rest of the range sits under lab glassware.
Customer Reviews
Discover More from Xin Tester
Pear-Shaped Separatory Funnel, Borosilicate 3.3 Glass with Glass Stopcock (60ml-1000ml)
$12.51 – $28.33Price range: $12.51 through $28.33
🚚 Delivery: as soon as Thu. Dec 17
Xin Tester GL45 Reagent Bottle, 100ml-20L Boro 3.3 Glass with Anti-Slip Bottom
$19.91 – $286.00Price range: $19.91 through $286.00
🚚 Delivery: as soon as Thu. Dec 17
Glass Ampoules, Clear & Amber Empty Vials with Easy-Break Neck (1ml-20ml) by Xin Tester
$12.84 – $52.78Price range: $12.84 through $52.78
🚚 Delivery: as soon as Thu. Dec 17
Xin Tester Glass Vacuum Filtration Apparatus Assembly (250-1000ml)
$60.87 – $68.98Price range: $60.87 through $68.98
🚚 Delivery: as soon as Thu. Dec 17


































Reviews
There are no reviews yet