Sale!

Features & Details

⚡ 4-WIRE SOIL RESISTIVITY Measures soil resistivity (ρ from 0.00Ωm to 9000kΩm) using the Wenner 4-pole method with selectable auxiliary stake spacing from 1m to 100m.
📶 FFT ANTI-INTERFERENCE Fast Fourier Transform (FFT) digital filtering and AFC automated frequency control suppress industrial stray currents and ground voltages up to 600V.
📊 0.00Ω-30KΩ RANGE Supports 2-wire, 3-wire, and 4-wire testing modes with high 0.001Ω resolution across power substations, cellular towers, and pipeline grids.
💾 300-SET DATA STORAGE Large backlit LCD with clock timestamp, 300 measurement memory records, and USB interface to PC reporting software.

About this item

Measurement Function
Testing Range
Accuracy & Resolution

Core Measurement Capabilities
Earth Resistance (R)
0.00Ω ~ 30.00Ω
30.0Ω ~ 300.0Ω
300Ω ~ 3000Ω
3.00kΩ ~ 30.00kΩ
Acc: ±2%rdg ± 3dgt
Acc: ±2%rdg ± 3dgt
Acc: ±2%rdg ± 3dgt
Acc: ±4%rdg ± 3dgt
Soil Resistivity (ρ)
0.00Ωm ~ 99.99Ωm
100.0Ωm ~ 999.9Ωm
1000Ωm ~ 9999Ωm
Formula applied:
ρ = 2πaRa
Soil Resistivity [High]
10.00kΩm ~ 99.99kΩm
100.0kΩm ~ 999.9kΩm
1000kΩm ~ 9000kΩm
Electrode Distance:
a = 1m ~ 100m
Earth Voltage
AC 0.0 ~ 600V
Acc: ±2%rdg ± 3dgt

Testing Methodology & Engineering
Measurement Methods
✓ Earth Resistance: Precise 4-wire, 3-wire, and simple 2-wire (Rated current change-pole method)
✓ Soil Resistivity: Quadrupole method (Wenner method)
✓ Earth Voltage: Average value rectification (between P(S)-ES interfaces)
Testing Current & Frequency
Frequency: 128Hz / 111Hz / 105Hz / 94Hz (With Automatic Frequency Control AFC)
Short Circuit Current: AC 20mA max  |  Open Circuit Voltage: AC 40V max

Smart Diagnostics & Hardware Safety
Data Management
Data Storage: 300 sets with “MEM” indicator and “FULL” symbol
USB Interface: Real-time software monitoring, save, and print capabilities
Hardware Protection
Overload Protection: AC 280V / 3 seconds between C(H)-E and P(S)-ES ports
Withstand Voltage: AC 3700V/rms (between circuit and housing)
Interference Detection: “NOISE” symbol indicator if voltage exceeds 5V
Power Supply
DC 9V (Alkaline battery LR14 1.5V x 6)  |  Continuous Standby: Up to 300 hours

Grounding Grid Verification & Soil Geophysical Surveys

UNI-T UT523A Intelligent Earth Resistance Tester

Inadequate grounding grid impedance exposes industrial personnel to lethal touch potentials during lightning strikes and heavy ground faults. The UNI-T UT523A high-precision earth resistance tester incorporates 2/3/4-wire methods and automated Wenner soil resistivity calculation. Designed for power generation plants, telecom base stations, and railway infrastructure, it operates under heavy EMI environments. Explore our complete selections in the Resistance Meter catalog.

Wenner 4-Pole Soil Calculation

Automatically computes soil resistivity (ρ = 2πaR) once auxiliary stake spacing (a = 1m to 100m) is keyed in, eliminating complex manual field math during geological and lightning protection surveys.

FFT Digital Filtering Technology

Employs Fast Fourier Transform digital signal processing to separate small test currents from massive 50Hz/60Hz industrial stray ground currents, ensuring stable readings even near live high-voltage transformers.

Heavy-Duty Field Kit Inclusions

Supplied inside an impact-resistant waterproof rugged case containing 4 auxiliary ground rods, 4 color-coded test wire reels, 2 simple test leads, USB cable, and software CD.

Related testing & equipment:
Digital Clamp Meter |
Electrical Measuring Instruments

Related products:
Bluetooth ground resistance clamp

FAQs

A: Standard 2-wire tests cannot accurately measure deep soil composition. However, the Wenner 4-pole method utilizes four equally spaced ground spikes. Specifically, it injects current through the outer spikes and measures voltage internally. Consequently, it calculates the exact soil resistivity deep underground flawlessly.

A: Testing grounding systems near power substations exposes meters to massive AC noise. Fortunately, the Fast Fourier Transform (FFT) filters out these chaotic frequencies digitally. Additionally, the Automatic Frequency Control (AFC) shifts the testing signal away from active noise. Ultimately, your readings remain completely pure.

A: Yes, you certainly can. Before measuring resistance, you must check for dangerous stray currents. Specifically, this device measures Earth Voltage up to 600V AC instantly. Therefore, you can verify if the ground line is carrying a dangerous fault charge securely.

A: No, you do not. This professional kit arrives completely ready for fieldwork. Specifically, we include the necessary auxiliary earth spikes natively. Furthermore, it contains standard test leads, simple test leads, and a durable carrying strap. Thus, you can begin commercial diagnostics immediately.

UNI-T UT523A Earth Resistance Tester, Intelligent 4-Wire Soil Resistivity & Earth Voltage Meter with FFT Anti-Interference

Original price was: $799.99.Current price is: $729.99.

6–12 Month Warranty

Repair & Refund support available for most products.

Free Worldwide Shipping

Ships within 3 business days.

Taxes & Duties

Buyer responsible for local import fees.

24/7 After-Sales Support

Technical assistance & video guidance within 24h.

UNI-T UT523A Earth Resistance Tester, Intelligent 4-Wire Soil Resistivity & Earth Voltage Meter with FFT Anti-Interference

Sale!

Original price was: $799.99.Current price is: $729.99.

Features & Details

⚡ 4-WIRE SOIL RESISTIVITY Measures soil resistivity (ρ from 0.00Ωm to 9000kΩm) using the Wenner 4-pole method with selectable auxiliary stake spacing from 1m to 100m.
📶 FFT ANTI-INTERFERENCE Fast Fourier Transform (FFT) digital filtering and AFC automated frequency control suppress industrial stray currents and ground voltages up to 600V.
📊 0.00Ω-30KΩ RANGE Supports 2-wire, 3-wire, and 4-wire testing modes with high 0.001Ω resolution across power substations, cellular towers, and pipeline grids.
💾 300-SET DATA STORAGE Large backlit LCD with clock timestamp, 300 measurement memory records, and USB interface to PC reporting software.

Measurement Function
Testing Range
Accuracy & Resolution

Core Measurement Capabilities
Earth Resistance (R)
0.00Ω ~ 30.00Ω
30.0Ω ~ 300.0Ω
300Ω ~ 3000Ω
3.00kΩ ~ 30.00kΩ
Acc: ±2%rdg ± 3dgt
Acc: ±2%rdg ± 3dgt
Acc: ±2%rdg ± 3dgt
Acc: ±4%rdg ± 3dgt
Soil Resistivity (ρ)
0.00Ωm ~ 99.99Ωm
100.0Ωm ~ 999.9Ωm
1000Ωm ~ 9999Ωm
Formula applied:
ρ = 2πaRa
Soil Resistivity [High]
10.00kΩm ~ 99.99kΩm
100.0kΩm ~ 999.9kΩm
1000kΩm ~ 9000kΩm
Electrode Distance:
a = 1m ~ 100m
Earth Voltage
AC 0.0 ~ 600V
Acc: ±2%rdg ± 3dgt

Testing Methodology & Engineering
Measurement Methods
✓ Earth Resistance: Precise 4-wire, 3-wire, and simple 2-wire (Rated current change-pole method)
✓ Soil Resistivity: Quadrupole method (Wenner method)
✓ Earth Voltage: Average value rectification (between P(S)-ES interfaces)
Testing Current & Frequency
Frequency: 128Hz / 111Hz / 105Hz / 94Hz (With Automatic Frequency Control AFC)
Short Circuit Current: AC 20mA max  |  Open Circuit Voltage: AC 40V max

Smart Diagnostics & Hardware Safety
Data Management
Data Storage: 300 sets with “MEM” indicator and “FULL” symbol
USB Interface: Real-time software monitoring, save, and print capabilities
Hardware Protection
Overload Protection: AC 280V / 3 seconds between C(H)-E and P(S)-ES ports
Withstand Voltage: AC 3700V/rms (between circuit and housing)
Interference Detection: “NOISE” symbol indicator if voltage exceeds 5V
Power Supply
DC 9V (Alkaline battery LR14 1.5V x 6)  |  Continuous Standby: Up to 300 hours

Grounding Grid Verification & Soil Geophysical Surveys

UNI-T UT523A Intelligent Earth Resistance Tester

Inadequate grounding grid impedance exposes industrial personnel to lethal touch potentials during lightning strikes and heavy ground faults. The UNI-T UT523A high-precision earth resistance tester incorporates 2/3/4-wire methods and automated Wenner soil resistivity calculation. Designed for power generation plants, telecom base stations, and railway infrastructure, it operates under heavy EMI environments. Explore our complete selections in the Resistance Meter catalog.

Wenner 4-Pole Soil Calculation

Automatically computes soil resistivity (ρ = 2πaR) once auxiliary stake spacing (a = 1m to 100m) is keyed in, eliminating complex manual field math during geological and lightning protection surveys.

FFT Digital Filtering Technology

Employs Fast Fourier Transform digital signal processing to separate small test currents from massive 50Hz/60Hz industrial stray ground currents, ensuring stable readings even near live high-voltage transformers.

Heavy-Duty Field Kit Inclusions

Supplied inside an impact-resistant waterproof rugged case containing 4 auxiliary ground rods, 4 color-coded test wire reels, 2 simple test leads, USB cable, and software CD.

Related testing & equipment:
Digital Clamp Meter |
Electrical Measuring Instruments

Related products:
Bluetooth ground resistance clamp

Customer Reviews

Reviews

There are no reviews yet

Add a review
You must be logged in to post a review Log In

Discover More from Xin Tester